DC-JMDDR SDRAM DIMM Memory 256MB
DC-M
Xem cỡ ảnh lớn

DC-M




Easy operation, clear display & easy pre-set

Feature

  • All models provide increment/decrement counting and this counter can apply to wide range of application because of free voltage, 100 to 240VAC.

Specifications

72×72mm type

Type

Increment/decrement type total counter

Increment/decrement type preset counter

Model No.

DC-MA6-D

DC-MB6-D

Display

Red LED 7-segment LED(Height10mm, width5.7mm), Range: 999999 to -99999 (Zero-suppress)

Number of digit

6 digits

Power source

100 to 240VAC(50/60Hz)

Fluctuation range

-15% to +10%

Power consumption

Approx. 4.5VA(when 240VAC)

Counting

Contact/transistor open-collector input : Counting when OFF→ON, voltage input: Counting when “L”→“H”

Preset


1

Preset method


Digital switch for each digit

Counting speed

30Hz: Min. signal width 16.7msec, make-ratio 1:1
5kHz: Min. signal width 100μsec, make-ratio 1:1(Changeover by slide switch)

Counting prohibited

Prohibited when ON("H" level in case of voltage input)Response time: 16msec or less(when 30Hz), 100μsec or less(when 5kHz)

Counting/ reset/counting prohibited input

Contact/transistor open-collector input Impedance(ZON): 1kΩ or less when ON(Short-circuit), Impedance(ZOFF): 5kΩ or more when OFF(Opened)

Control output operation

Self-holding operation: It operates when preset value and returns by reset
Single-shot operation: It operates when preset value and returns after specific time(200ms)

Power source for sensor

12VDC(+10%, -10%), 100mA(Ripple 5% or less)

Ambient temperature, humidity

-10 degrees C to +45 degrees C(-20 degrees C to +55 degrees C when stored) 45 to 85%RH

Memory time against power failure

Memory time/once: approx. 10 years, memory numbers: 0.1 million times

Case

Case: ABS resin, dust-proof cover: polycarbonate

Attachment

Dust-proof cover, fitting metal

 


72×144mm type

Type

Increment/decrement type total counter

Increment/decrement type preset counter

Increment/decrement type 2-preset counter

Model No.

DC-MA6-E

DC-MB6-E

DC-MC6-E

Display

Red LED 7-segment LED(Height15mm, width8.8mm), Range: 999999 to -99999 (Zero-suppress)

Number of digit

6 digits

Power source

100 to 240VAC(50/60Hz)

Fluctuation range

-15% to +10%

Power consumption

約4.5VA(when 240VAC)

Counting

Contact/transistor open-collector input : Counting when OFF→ON, voltage input: Counting when “L”→“H”

Preset


2

Preset method


Digital switch for each digit

Counting speed

30Hz: Min. signal width 16.7msec, make-ratio 1:1
5kHz: Min. signal width 100μsec, make-ratio 1:1(Changeover by slide switch)

Counting prohibited

Prohibited when ON("H" level in case of voltage input)Response time: 16msec or less(when 30Hz), 100μsec or less(when 5kHz)

Counting/ reset/counting prohibited input

Contact/transistor open-collector input Impedance(ZON): 1kΩ or less when ON(Short-circuit), Impedance(ZOFF): 5kΩ or more when OFF(Opened)

Control output operation

Self-holding operation: It operates when preset value and returns by reset
Single-shot operation: It operates when preset value and returns after specific time(200ms)

Power source for sensor

12VDC(+10%, -10%), 100mA(Ripple 5% or less)

Ambient temperature, humidity

-10 degrees C to +45 degrees C(-20 degrees C to +55 degrees C when stored) 45 to 85%RH

Memory time against power failure

Memory time/once: approx. 10 years, memory numbers: 0.1 million times

Case

Case: ABS resin, dust-proof cover: polycarbonate

Attachment

Dust-proof cover, fitting metal

* DC-MOW with BCD read-out output is also lined up. Ask us in details.

External dimension

72×72mm type


Panel-cut dimension


72×144mm type


Panel-cut dimension

Connection

Input/transister output

Contact/transister open-collector input

Voltage input


Connection

DC-M_Connection 72×72mm type

Contact/Open-collector input

Note) Count 1 terminal [8] is increment, Count 2 terminal [9] is decrement. In case of 90 phase-difference input, when Count 1 is shifted shifted by 90°, it is increment counting, and when Count 2 is shifted 90°, it is decrement counting.
Note) In case of Total counter, [4] [5] [6] terminal are not used.
Note) FG [3] terminals should be grounded.


DC-M_Connection 2×144mm type

Contact/Open-collector input

Note) Terminals [11] and [18] are connected inside
Note) Count 1 [12] is increment counting and Count 2 [13] is decrement counting. In case of 90°phase-difference input, when Count 1 is shifted by 90°, it is increment counting, and when Count 2 is shited by 90°, it is decrement counting.
Note) In case of total counter, [4] [5] [6] [7] [8] [9] [16] [17] terminals are not used.
Note) In case of preset counter (1 preset type), [4] [5] [6] [16] terminals are not used.
Note) FG ([3] terminal) should be grounded.

 

Caution note)

* Do not use unused terminal as relay terminal.
* Each input to counting, reset and count prohibition is common use for contact and open-collector. Wire to each input and output terminal 2-core shield wire or metal conduit tube as short as possible. Do not lay the wires close to or parallel to line cable, power cable or high voltage line.
* For connection, use M3 pressure connection terminals.


Các sản phẩm cùng loại
Total counter
Total counter
DC-JB/JC
DC-JB/JC
Electronic counter with DIN size
Electronic counter with DIN size
DC-JA
DC-JA
Electronic counter with DIN size
Electronic counter with DIN size
LED display DIN size Electronic counter
LED display DIN size Electronic counter
DC-JM
DC-JM

Joomlart
Designed: Hien Dai Hoa Jsc

lien ke van Canh HUD, du an van canh HUD, biet thu van Canh Hud, du an GELEXIMCO, du an cua HUD, biet thu tay nam linh dam, du an tay nam Linh Dam, du an xuan ngoc xuan phuong, biet thu xuan ngoc xuan phuong, lien ke xuan phuong xuan ngoc, du an TASCO, biet thu nam an khanh, du an nam an khanh sudico, lien ke nam an khanh sudico , biet thu nam an khanh sudico, du an nam an khanh, tranh tuong