Model No.
|
UBG-05LN
|
Power source
|
24VDC(available operating range 18 to 30VDC, ripple within 10%)
|
Current consumption
|
150mA or less but rush current 300mA is required when start-up(when 24VDC)
|
Light source
|
Semiconductor laser diode(λ=785nm), Laser safety class 1(FDA)
|
Detectable object
|
White paper with 125□(Installing in parallel with projecting/receiving surface)
|
Detecting range
|
Area with 0.1 to 5m(length) and 4m(width)(origin point is the scanning center)
|
Accuracy*1
|
±20mm at 1m or less, 2% of measurement at 1m or more
|
Repeatability*1
|
±10mm at 1m or less, 2% of measurement at 1m or more
|
Detecting are setting
|
Output 1 : It is free to set from 0 to 5m for optical axis direction with 7 points pointer. Output 2, 3 : (1) Linear setting to progressive direction (2) Fan-shaped setting to optical axis direction (3) Percentage(%) setting against output 1 pointer
|
Hysteresis
|
6.25% of detecting distance
|
Output
|
Photo-coupler/open-collector output(30VDC 50mA or less) Output 1 : OFF when detected in area Output 2 : OFF when detected in area Output 3 : OFF when detected in area Output 4(Trouble output) : ON during normal operationNote1)
|
Output response time
|
210msec or less(scanning speed 100msec/rev.)Note2)
|
Input
|
Photo-coupler input(Anode common, Each input ON current 4mA) Detecting area changeover Set area No. by [Input 1], [Input 2], [Input 3], [Input 4] and [Input 5] Emission-stop by getting all [Input 1], [Input 2], [Input 3], [Input 4] and [Input 5] to ON(OFF : H level input, ON : L level input)
|
Input response time
|
Input taking-in cycle : 1 scanning time(100msec) (1msec when choosing emission-stop by outer input
|
Starting time
|
within 10sec from putting power source on(It may exceed this time depending on the starting condition)
|
Indicators
|
Power lamp(Green) : Flickers when troubled or started Output 1 lamp(Orange) : Lights up when detected in area Output 2 lamp(Orange) : Lights up when detected in area Output 3 lamp(Orange) : Lights up when detected in area
|
Connection
|
Cable 1m long
|
Ambient illuminanceNote 3)
|
Halogen/mercury lamp : 10,000lx or less, Fluorescent lamp : 6,000lx(Max.)
|
Ambient temperature/ humidity
|
-10 to +50 degrees C, 85%RH or less(Not condensing, not icing)
|
Vibration resistance
|
10 to 55Hz, double amplitude 1.5mm Each 2 hour in X, Y and Z directions
|
Impact resistance
|
196m/s2 Each 10 time in X, Y and Z directions
|
Protective structure
|
IP64(IEC standard)
|
Weight
|
185g(260g with cable)
|
Life
|
5 years(motor life)
|
Material
|
Front case : polycarbonate, rear case : ABS
|