PBS-03JN
|
|
24VDC(Allowable range 18 to 30VDC including ripple)
|
|
250mA or less(100mA or less when emission stops) Except for I/O terminal current and rush current(500mA)
|
|
|
Detectable object and detection area
|
White paper with 300×300mm(Placed in parallel with sensor projection surface), 0.2 to 3m×2m(Origin point is scanning center position) but within scanning angle 180°
|
|
|
It is free to set from 0 to 10m for optical axis direction with 7 points pointer.
|
|
Linear setting to progressive direction, fan-shaped setting to optical axis direction, Percentage(%) setting against output 1 pointer
|
|
When each detecting area setting, it sets individually for each output.
|
|
10% or less of detection distance(it is not getting 60mm or less)
|
|
Photo-coupler/NPN open-collector output(30VDC 50mA or less) Output 1,2,3 : output OFF when detecting within area, trouble output : output ON when normal operation*
|
|
Photo-coupler input(Anode common, each input current 4mA or more), This can changes setting detection area.
|
|
It set the area No. by Input 1, 2, 3 and 4 It stops the emission by getting all Input 1, 2, 3 and 4 to ON(OFF : H level input, ON : L level input)
|
|
180msec or less(Scanning speed 1 rev./100msec) 280msec or less when 2 scanning mode(but except for 100msec, area changeover time)
|
|
Input taking-in cycle : 1 scanning time(100msec)
|
|
Power lamp(Green) : Flickered when trouble Output 1, 2 and 3 lamp(Orange) : Lights up when detected in area
|
|
|
Ambient illuminance(note)
|
Halogen/mercury lamp : 10,000lx or less, Fluorescent lamp : 6,000lx or less
|
Ambient temperature/humidity
|
-10 to +50 degrees C, 85%RH or less(Not condensing, not icing)
|
|
10 to 55Hz, double amplitude 1.5mm Each 2 hour in X, Y and Z directions
|
|
490m/s2, Each 10 time in X, Y and Z directions
|
|
|
|
|
|
Front case : Polycarbonate, rear case : ABS
|
|
|