DMH-GC/HCDMS
DMM-GB/HB
Xem cỡ ảnh lớn

DMM-GB/HB




This device is able to connect directly to CC-Link system.
8-bit type deice can communicate with DMS-GB/HB and DMG-GB/HB and 16-bit type can communicate with DMS-GC/HC. It is possible to connect maximum 64 units to one master unit.

Specifications

Model No.

DMM-GB1

DMM-HB1

DMM-GC1

DMM-HC1

Direction

HEAD-ON

SIDE-ON

HEAD-ON

SIDE-ON

Power source

24VDC(18 to 30VDC available)

Optical communication part

Transmission distance

0 to 1m*1

0 to 3m*2

Directional angle

Full angle 30°

Full angle 26°

Transmission capacity(I/O)

8BIT/8BIT

16BIT/16BIT*3

Transmission method

Half-duplex two-way transmission

Transmission time

40ms

Modulation method

Pulse modulation

FSK modulation

Detection method

Parity check

CC-Link part

Transmission speed

10Mbps/5Mbps/2.5Mbps/625kbps/156kbps(Changeover by switch)

Communication system

Polling system

Synchronous system

Frame synchronous system

Transmission path

RS-485bus

Remote station Nos.

1 to 64

Occupied station

1 station

Connecting cable

CC-Link exclusive cable and CC-Link high quality cable

Max. extending cable*4

Speed(bps): 10Mbps, 5Mbps, 2.5Mbps, 625kbps, 156kbps
Exclusive cable: 100m, 150m, 200m, 600m, 1,200m
High quality cable: 100m, 160m, 400m, 900m, 1,200m

Connecting system

Connector type(5 pins)

Ambient temperature/ humidity

-10 to +50 degrees C, 85%RH or less(Not condensing)

Ambient illuminance

Halogen 4,000 lx or less, mercury lamp 4,000 lx or less

*1. 3m type is also available.
*2. Distance can be changed by adjuster.
*3. 16th bit can be changed to Select input/GO output by input changeover switch.
*4. Total extended distance changes depending on total
External dimension

External dimension

Connection

5P side(CC-Link connection)

Signals

Functions

Position

DA

Signal cable

1

DAR

Terminator provided

2

DB

Signal cable

3

DG

Signal GND cable

4

SLD

Shield cable

5

Note) If this device is connected to terminator, it is shorted between DA and DAR by the wire with 1mm.

3P side(Power source)

Signals

Functions

Position

FG

Ground

1

+24V

DC power

2

+0V

DC power

3

Note) Don't make a wiring with main circuit, high-voltage line or load wire because it is not affected by noise and surge induction.


Các sản phẩm cùng loại
BWF-17/27
BWF-17/27
DMC-GB1/HB1
DMC-GB1/HB1

Joomlart
Designed: Hien Dai Hoa Jsc

lien ke van Canh HUD, du an van canh HUD, biet thu van Canh Hud, du an GELEXIMCO, du an cua HUD, biet thu tay nam linh dam, du an tay nam Linh Dam, du an xuan ngoc xuan phuong, biet thu xuan ngoc xuan phuong, lien ke xuan phuong xuan ngoc, du an TASCO, biet thu nam an khanh, du an nam an khanh sudico, lien ke nam an khanh sudico , biet thu nam an khanh sudico, du an nam an khanh, tranh tuong