High accuracy measurement enabled by the combination of high sensitivity linear image sensor and electronic shutter
Feature
- Linearity ±0 .1% of FS with high sensitivity image sensor
- High-speed displacement sensor with sampling cycle 100µsec
- Amplifier integrated monitor with controller
- Bank function with 8 channels
- Hard to be affected by color, gloss or material of objects
- 5 kinds of individual comparator output
- Easy to handle with simple button and color LCD
- IP67 for sensor head
Typical applications
|
Swing measurement(swing of slitter) |
Slip measurement(slip of roller) |
|
|
|
|
Height measurement(pull-top position)
|
Warp measurement(warp of PCB)
|
|
|
|
|
Thickness measurement(Thickness of board)
|
Thickness measurement(Thickness of wafer)
|
|
|
Caution
Caution about laser beam
This product is emitting visible laser beam and is classified as Class 1 or 2 by JIS C6802/IEC Laser Safety standard. When exporting to USA, US laser control, FDA(Food and Drug Administration) is applied. Please ask us in details.
|
|
|
|
Ultra high accuracy(Class 1)
|
High accuracy(Class 2)
|
|
|
Specifications
Sensor head
Kinds
|
Ultra-high accuracy
|
High accuracy(short)
|
High accuracy(middle)
|
High accuracy(long)
|
Model No.
|
HXA-25KL
|
HXA-30K
|
HXA-85K
|
HXA-350K
|
Optical system
|
Direct reflection
|
Diffuse reflection
|
Measuring range
|
|
30mm±5mm
|
85mm±20mm
|
350mm±100mm
|
Light source
|
Red semiconductor laser 650nm
|
Laser class
|
|
IEC/JIS class 2
|
Max. power
|
|
|
Laser life
|
Approx. 50,000 hours(at 40 degrees C)
|
Spot diameter*1
|
|
Approx. 30×100µm
|
Approx. 70×290µm
|
Approx. 300×700µm
|
Linearity*2
|
|
Resolution*3
|
0.1µm
|
1µm
|
3µm
|
40µm
|
Temperature drift
|
|
Indication lamps
|
Laser emitting lamp : Green LED(Lights up when emitting), Measuring range lamp : Red LED(short side), orange LED(center), green LED(long side) red/green mutual blinking(out of measuring, impossible measuring)
|
Connection
|
|
Ambient illuminance
|
Incandescent lamp : 3,000lx or less, sun light : 10,000lx or less
|
Ambient temperature/humidity
|
-10 to +45 degrees C(-20 to +60 degrees C when stored), 35 to 85%RH(35 to 85%RH when stored) but not icing, not condensing
|
Vibration resistance
|
Double amplitude 1.5mm, 10 to 55Hz, each 2 hour for X, Y and Z direction
|
Impact resistance
|
498m/s2, each 3 times in X, Y and Z direction
|
Withstand voltage
|
1000VAC/min.
|
Insulation resistance
|
20MΩ(500VDC) or more
|
Protective structure
|
|
Case material
|
Main body : aluminum die-casting, window : glass
|
Weight
|
|
Cable extension
|
Max. 10m
|
Accessory
|
|
*1 It is definition with the center strength, 1/e2(13.5%) at the center of measuring. There is leakage light except for the specified spot size and in case of the objects with high reflectance around detecting distance, it may be affected. *2 This value is for average numbers, 256 times(with exclusive amplifier) and white ceramic(when glass measuring for XHA-25KL) *3 This is typical value at the center of measuring for average numbers, 256 times(with exclusive amplifier). It may be changed depending on the objects.
Amplifier
Kinds
|
Ultra-high accuracy for HXA-25KL
|
High accuracy for HXA-30K/80K/350K
|
Model No.
|
LXA-DCL
|
LXA-DC
|
Code No.
|
|
|
Power source
|
12 to 24VDC ±10%
|
Current consumption
|
270mA when 24VDC(including 2 pcs of sensor head and analog output current)
|
Max. connectable numbers
|
Max. 2 pcs
|
Sampling cycle
|
100µs
|
Temperature drift
|
±0.01$ F.S/degrees C
|
Control output
|
NPN open-collector output, 100mA 24VDC or less(residual voltage 1.8V or less), 5 output(individual setting is available), Hysteresis setting is available
|
Analog output
|
Voltage output : ±5V/F.S.(Output impedance 100Ω, resolution 1mV) Current output : 4 to 20mA/F.S.(Load impedance 300Ω or less, resolution 1.5µA)
|
Alarm output
|
NPN open-collector output 100mA 24VDC or less(residual voltage 1.8V or less), On when sensor head fails in measurement
|
Bank input
|
On when connecting to GND, 8 banks(8 patterns of measuring condition can be registered or changed)
|
Hold input
|
On when connecting to GND, Laser off or measuring value is held(set by menu)
|
Zero reset input
|
On when connecting to GND, Zero reset is available for Head A value, head B value and calculating value
|
Optional functions
|
Average sampling times, filter mode(cut-off frequency), calculation, hold setting output during alarm, output control(hysteresis), Analog output, sensor head sensitivity control, timer function, memory function, bank function, auto-zero reset
|
Circuit stable time
|
5min. or less
|
Display
|
LCD
|
Connection
|
Terminal stand
|
Ambient temperature/humidity
|
-10 to +45 degrees C(-20 to +60 degrees C when stored), 35 to 85%RH(35 to 85%RH when stored) but not icing, not condensing
|
Vibration resistance
|
Double amplitude 1.5mm, 10 to 55Hz, each 2 hour for X, Y and Z direction
|
Impact resistance
|
196m/s2, each 3 times in X, Y and Z direction
|
Withstand voltage
|
1000VAC/min.
|
Insulation resistance
|
20MΩor more(500VDC)
|
Protective structure
|
IP20(IEC standard)
|
Case material
|
Body : polycarbonate, terminal box : nylon 66
|
Weight
|
240g(including terminal box)
|
Accessory
|
Terminal box
|
External dimension
Sensor head
|
Ultra-high accuracy type
|
High accuracy type
|
|
|
|
*1 Value for HXA-30K. HXA-85K : 42.3, HXA-350K : 50 *2 Value for HXA-30K/85K. HXA-350K : 27
|
|
Amplifier
|
I/O circuit
|
|
|
Input/output circuit
Input circuit(bank input, hold input, zero-reset input)
|
|
|
|
|
|
Output circuit(Control output, alarm output)
|
Output circuit(Analog output(A/B))
|
|
|
|