Easy operation, clear display & easy pre-set
Feature
- All models provide increment/decrement counting and this counter can apply to wide range of application because of free voltage, 100 to 240VAC.
Specifications
72×72mm type
|
Increment/decrement type total counter
|
Increment/decrement type preset counter
|
Model No.
|
DC-MA6-D
|
DC-MB6-D
|
|
Red LED 7-segment LED(Height10mm, width5.7mm), Range: 999999 to -99999 (Zero-suppress)
|
|
|
|
|
|
|
|
Approx. 4.5VA(when 240VAC)
|
|
Contact/transistor open-collector input : Counting when OFF→ON, voltage input: Counting when “L”→“H”
|
|
|
|
|
|
Digital switch for each digit
|
|
30Hz: Min. signal width 16.7msec, make-ratio 1:1 5kHz: Min. signal width 100μsec, make-ratio 1:1(Changeover by slide switch)
|
|
Prohibited when ON("H" level in case of voltage input)Response time: 16msec or less(when 30Hz), 100μsec or less(when 5kHz)
|
Counting/ reset/counting prohibited input
|
Contact/transistor open-collector input Impedance(ZON): 1kΩ or less when ON(Short-circuit), Impedance(ZOFF): 5kΩ or more when OFF(Opened)
|
|
Self-holding operation: It operates when preset value and returns by reset Single-shot operation: It operates when preset value and returns after specific time(200ms)
|
|
12VDC(+10%, -10%), 100mA(Ripple 5% or less)
|
Ambient temperature, humidity
|
-10 degrees C to +45 degrees C(-20 degrees C to +55 degrees C when stored) 45 to 85%RH
|
Memory time against power failure
|
Memory time/once: approx. 10 years, memory numbers: 0.1 million times
|
|
Case: ABS resin, dust-proof cover: polycarbonate
|
|
Dust-proof cover, fitting metal
|
72×144mm type
|
Increment/decrement type total counter
|
Increment/decrement type preset counter
|
Increment/decrement type 2-preset counter
|
|
DC-MA6-E
|
DC-MB6-E
|
DC-MC6-E
|
|
Red LED 7-segment LED(Height15mm, width8.8mm), Range: 999999 to -99999 (Zero-suppress)
|
|
|
|
|
|
|
|
|
|
Contact/transistor open-collector input : Counting when OFF→ON, voltage input: Counting when “L”→“H”
|
|
|
|
|
|
|
Digital switch for each digit
|
|
30Hz: Min. signal width 16.7msec, make-ratio 1:1 5kHz: Min. signal width 100μsec, make-ratio 1:1(Changeover by slide switch)
|
|
Prohibited when ON("H" level in case of voltage input)Response time: 16msec or less(when 30Hz), 100μsec or less(when 5kHz)
|
Counting/ reset/counting prohibited input
|
Contact/transistor open-collector input Impedance(ZON): 1kΩ or less when ON(Short-circuit), Impedance(ZOFF): 5kΩ or more when OFF(Opened)
|
|
Self-holding operation: It operates when preset value and returns by reset Single-shot operation: It operates when preset value and returns after specific time(200ms)
|
|
12VDC(+10%, -10%), 100mA(Ripple 5% or less)
|
Ambient temperature, humidity
|
-10 degrees C to +45 degrees C(-20 degrees C to +55 degrees C when stored) 45 to 85%RH
|
Memory time against power failure
|
Memory time/once: approx. 10 years, memory numbers: 0.1 million times
|
|
Case: ABS resin, dust-proof cover: polycarbonate
|
|
Dust-proof cover, fitting metal
|
* DC-MOW with BCD read-out output is also lined up. Ask us in details.。
External dimension
72×72mm type
|
|
|
|
Panel-cut dimension
|
|
72×144mm type
|
|
|
|
Panel-cut dimension
|
|
Connection
Input/transister output
Contact/transister open-collector input
|
Voltage input
|
|
|
Connection
DC-M_Connection 72×72mm type
Contact/Open-collector input
Note) Count 1 terminal [8] is increment, Count 2 terminal [9] is decrement. In case of 90 phase-difference input, when Count 1 is shifted shifted by 90°, it is increment counting, and when Count 2 is shifted 90°, it is decrement counting. Note) In case of Total counter, [4] [5] [6] terminal are not used. Note) FG [3] terminals should be grounded.
DC-M_Connection 2×144mm type
Contact/Open-collector input
Note) Terminals [11] and [18] are connected inside Note) Count 1 [12] is increment counting and Count 2 [13] is decrement counting. In case of 90°phase-difference input, when Count 1 is shifted by 90°, it is increment counting, and when Count 2 is shited by 90°, it is decrement counting. Note) In case of total counter, [4] [5] [6] [7] [8] [9] [16] [17] terminals are not used. Note) In case of preset counter (1 preset type), [4] [5] [6] [16] terminals are not used. Note) FG ([3] terminal) should be grounded.
Caution note)
* Do not use unused terminal as relay terminal. * Each input to counting, reset and count prohibition is common use for contact and open-collector. Wire to each input and output terminal 2-core shield wire or metal conduit tube as short as possible. Do not lay the wires close to or parallel to line cable, power cable or high voltage line. * For connection, use M3 pressure connection terminals.
|